| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Battery Size and Type | Battery life | Cable Length | Cable Length Note | Compliance | Data Interface | Data Interface Note | Display Type | Display Type Note | Electrical Output | Electrical Output Note | Enclosure Material | Enclosure Ratings | Hi-Side Containment Pressure | Isolation between Case and Output Terminations, Min | Length | Line/Static Pressure | Line/Static Pressure Note | Materials, Wetted | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Batteries | Number of Digits | Operating Temperature, Max | Operating Temperature, Min | Output Signal | Pressure Accuracy | Pressure Cycles | Process Connection Size | Process Connection Type | Proof Pressure | Sample Display Rate Note | Sample/Display Rate | Sensor Dimension Note | Settable Parameters | Software Compatibility | Software Settings | Stability | Storage Temperature, Max | Storage Temperature, Min | Supply Power Note | Supply Power Type | Thermal Effects | Weight | Weight Note | Width | Wireless Band | Wireless Option Specifications | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPGM409-3.5BDWU-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 3.5 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-170HDWU-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 170 mBar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-350HDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 350 mBar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-17.5BDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 17.5 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-3.5BDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 3.5 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-170HDWU3,349,050 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 170 mBar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-070HDWU3,349,050 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 70 mBar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 6x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-035BDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 35 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-010BDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 10 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-025HDWU3,349,050 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 25 mBar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 10x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-007BDWU3,198,270 원19 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 7 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-002BDWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 2 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-001BDWU가격 문의22 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) | 3.6V Li-ion | up to 4 yr | 2.7 m | 2.7 m (9') with ferrite core (included) | CE | USB | USB connection for set-up, cable included | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 89 mm | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 1 bar | 0 mBar | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 4x Full Scale | User selectable from 0.38 to 30 seconds (preset to 1/second) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP, Vista | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | ± 0.1% | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span | 1 kg | 1 kg (2.2 lb) typical depending upon configuration | 80 mm | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. |