제품 사양
Brand:OMEGA Engineering
Accuracy Class:< 0.1%
Accuracy Detail:± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m)
Battery Size and Type:3.6V Li-ion
Battery life:up to 4 yr
Cable Length:2.7 m
Cable Length Note:2.7 m (9') with ferrite core (included)
Compliance:CE
Data Interface:USB
Data Interface Note:USB connection for set-up, cable included
Display Type:LCD
Display Type Note:4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height.
Electrical Output:4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
Electrical Output Note:User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA
Enclosure Material:316 Stainless Steel
Enclosure Ratings:IP65, NEMA Type 4X, Weatherproof
Hi-Side Containment Pressure:1000 psi
Isolation between Case and Output Terminations, Min:100MΩ @ 50 Vdc
Length:89 mm
Line/Static Pressure:500 psi
Line/Static Pressure Note:500 psi maximum applied to both sides simultaneously
Materials, Wetted:316 Stainless Steel
Measurement Pressure Type:Differential
Measurement Pressure, Max:170 mBar
Measurement Pressure, Min:0 mBar
Number of Batteries:1
Number of Digits:4
Operating Temperature, Max:66 °C
Operating Temperature, Min:-18 °C
Output Signal:Current, Voltage
Pressure Accuracy:± 0.08 %
Pressure Cycles:1 million minimum
Process Connection Size:1/4 in
Process Connection Type:BSPP Male
Proof Pressure:4x Full Scale
Sample Display Rate Note:User selectable from 0.38 to 30 seconds (preset to 1/second)
Sample/Display Rate:0.38 to 30 seconds
Sensor Dimension Note:72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide"
Settable Parameters:Backlight, Min, Max, Zero, Clear
Software Compatibility:Requires Windows® 7 (32 bit); XP, Vista
Software Settings:Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _”
Stability:± 0.1%
Storage Temperature, Max:82 °C
Storage Temperature, Min:-40 °C
Supply Power Note:Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V)
Supply Power Type:Battery
Thermal Effects:Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span
Weight:1 kg
Weight Note:1 kg (2.2 lb) typical depending upon configuration
Width:80 mm
Wireless Band:None
Wireless Option Specifications:Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level.