로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 25개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Accessory Type | Accuracy | Accuracy Detail | Applications | Calibration Note | Compensated Temperature, Max | Compensated Temperature, Min | Compliance Note | Dimensions Note | Electrical Connection | Electrical Output | Enclosure Ratings | Factory Setting | Flow Rate Note | Galvanic Isolation | Height | Housing Material | Length | Load Resistance | Operating Pressure, Max | Operating Temperature, Max | Operating Temperature, Min | Process Connection Size | Process Connection Type | Repeatability | Response Time | Series ID | Storage Temperature, Max | Storage Temperature, Min | Supply Current | Supply Voltage | Weight | Measurement Type | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EA2-TX-AAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-ABA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-ABB가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-BAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-BBA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-BBB가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point, ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C, ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | MiniDIN 43650 form C L=132mm x ø45mm (with connector cable), MiniDIN 43650 form C L=132mm x ø45mm (with connector cable) | Mini DIN 43650 C | 4 to 20 mA | IP66, NEMA Type 4 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 132 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | 5/8 in | UNF Male | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-AAAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-AABA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-AABB가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-ABAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-ABBA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-BAAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-BABA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-BBAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-BBBA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-CAAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-CABA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-CBAA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-CBBA가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - | |
EA2-TX-M12-CBBB가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections | ± 2 °C (± 3.6 °F) | ±2°C (±3.6°F) dew point | Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications | Traceable 13-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C | M12 5 pin L = 155mm x ø45mm (with connector cable) | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040 | 155 mm | 316 Stainless Steel | 45 mm | Max 250 Ω @ 14 V (500 Ω @ 24 V) | 52.5 MPa | 60 °C | -40 °C | - | - | 0.5°C (0.9°F) dew point | 5 mins to T95 (dry to wet) | EA2-TX-M12 | 60 °C | -40 °C | 23 mA | 12 to 28 Vdc | 150 g | - |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.