총 5개의 상품
| 제품 번호 / 가격 | Accuracy | Accuracy Detail | Applications | Approvals | Calibration | Calibration Note | CO2 Measurement Range | Deadband | Diagnostics | Electrical Connection | Electrical Output | Enclosure Material | Enclosure Material Note | Installation | Material Construction Option | Measuring Range | Operating Humidity | Operating Temperature, Max | Operating Temperature, Min | Output Detail | Power Consumption | Relay Output | Repeatability | Response Time | Sensor Life | Sensor Type | Series ID | Storage Temperature, Max | Storage Temperature, Min | Supply Voltage | Temperature Measurement Range | Trip Point Note | Zero Drift | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TTL-232R-3V3가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ± 30 ppm, ±3 % | Extended Range Accuracy > 2,000 PPM: +/- 30 ppm and +/- 5% of reading; Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations | Air and HVAC, Building and Maintenance | EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU | Senseair ABC algorithm (Automatic Baseline Correction) | Calibration 3: Senseair ABC algorithm (Automatic Baseline Correction) | 0 to 2000 PPM | 100 ppm | Complete function check, yellow LED; LCD error indication (display model only) | Screw Terminal | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc | Polycarbonate/ABS Blend, UL94V-1 | ABS, Flammability Rating UL94-HB | 4-6’ o the floor | none | 7500 sq. ft. maximum | 0 to 85% RH, non-condensing | 122 °F | 32 °F | Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm Output 2 (Temperature): 0/2 to 10V, 0/4 to 20 mA, 32 to 122ºF (0 to 50ºC) | 1 W | 0.5 A @ 125 Vac; 1 A @ 24 Vdc | ±20 ppm ±1% of measured value | <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time | >15 years | Single beam infrared sensing technology (NDIR) | Asense-Room | 158 °F | -40 °F | 19 to 29 Vac/Vdc | -4 to 140ºF | 1000 ppm (factory set) | ± 0.3 % | |
ASENSE-R가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ± 30 ppm, ±3 % | Extended Range Accuracy > 2,000 PPM: +/- 30 ppm and +/- 5% of reading; Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations | Air and HVAC, Building and Maintenance | EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU | Senseair ABC algorithm (Automatic Baseline Correction) | Calibration 3: Senseair ABC algorithm (Automatic Baseline Correction) | 0 to 2000 PPM | 100 ppm | Complete function check, yellow LED; LCD error indication (display model only) | Screw Terminal | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc | Polycarbonate/ABS Blend, UL94V-1 | ABS, Flammability Rating UL94-HB | 4-6’ o the floor | none | 7500 sq. ft. maximum | 0 to 85% RH, non-condensing | 122 °F | 32 °F | Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm Output 2 (Temperature): 0/2 to 10V, 0/4 to 20 mA, 32 to 122ºF (0 to 50ºC) | 1 W | 0.5 A @ 125 Vac; 1 A @ 24 Vdc | ±20 ppm ±1% of measured value | <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time | >15 years | Single beam infrared sensing technology (NDIR) | Asense-Room | 158 °F | -40 °F | 19 to 29 Vac/Vdc | -4 to 140ºF | 1000 ppm (factory set) | ± 0.3 % | |
ASENSE-R-LCD가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ± 30 ppm, ±3 % | Extended Range Accuracy > 2,000 PPM: +/- 30 ppm and +/- 5% of reading; Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations | Air and HVAC, Building and Maintenance | EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU | Senseair ABC algorithm (Automatic Baseline Correction) | Calibration 3: Senseair ABC algorithm (Automatic Baseline Correction) | 0 to 2000 PPM | 100 ppm | Complete function check, yellow LED; LCD error indication (display model only) | Screw Terminal | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc | Polycarbonate/ABS Blend, UL94V-1 | ABS, Flammability Rating UL94-HB | 4-6’ o the floor | none | 7500 sq. ft. maximum | 0 to 85% RH, non-condensing | 122 °F | 32 °F | Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm Output 2 (Temperature): 0/2 to 10V, 0/4 to 20 mA, 32 to 122ºF (0 to 50ºC) | 1 W | 0.5 A @ 125 Vac; 1 A @ 24 Vdc | ±20 ppm ±1% of measured value | <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time | >15 years | Single beam infrared sensing technology (NDIR) | Asense-Room | 158 °F | -40 °F | 19 to 29 Vac/Vdc | -4 to 140ºF | 1000 ppm (factory set) | ± 0.3 % | |
ASENSE-R-LCD-REL가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ± 30 ppm, ±3 % | Extended Range Accuracy > 2,000 PPM: +/- 30 ppm and +/- 5% of reading; Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations | Air and HVAC, Building and Maintenance | EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU | Senseair ABC algorithm (Automatic Baseline Correction) | Calibration 3: Senseair ABC algorithm (Automatic Baseline Correction) | 0 to 2000 PPM | 100 ppm | Complete function check, yellow LED; LCD error indication (display model only) | Screw Terminal | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc | Polycarbonate/ABS Blend, UL94V-1 | ABS, Flammability Rating UL94-HB | 4-6’ o the floor | none | 7500 sq. ft. maximum | 0 to 85% RH, non-condensing | 122 °F | 32 °F | Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm Output 2 (Temperature): 0/2 to 10V, 0/4 to 20 mA, 32 to 122ºF (0 to 50ºC) | 1 W | 0.5 A @ 125 Vac; 1 A @ 24 Vdc | ±20 ppm ±1% of measured value | <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time | >15 years | Single beam infrared sensing technology (NDIR) | Asense-Room | 158 °F | -40 °F | 19 to 29 Vac/Vdc | -4 to 140ºF | 1000 ppm (factory set) | ± 0.3 % | |
ASENSE-R-REL가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ± 30 ppm, ±3 % | Extended Range Accuracy > 2,000 PPM: +/- 30 ppm and +/- 5% of reading; Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations | Air and HVAC, Building and Maintenance | EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU | Senseair ABC algorithm (Automatic Baseline Correction) | Calibration 3: Senseair ABC algorithm (Automatic Baseline Correction) | 0 to 2000 PPM | 100 ppm | Complete function check, yellow LED; LCD error indication (display model only) | Screw Terminal | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc | Polycarbonate/ABS Blend, UL94V-1 | ABS, Flammability Rating UL94-HB | 4-6’ o the floor | none | 7500 sq. ft. maximum | 0 to 85% RH, non-condensing | 122 °F | 32 °F | Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm Output 2 (Temperature): 0/2 to 10V, 0/4 to 20 mA, 32 to 122ºF (0 to 50ºC) | 1 W | 0.5 A @ 125 Vac; 1 A @ 24 Vdc | ±20 ppm ±1% of measured value | <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time | >15 years | Single beam infrared sensing technology (NDIR) | Asense-Room | 158 °F | -40 °F | 19 to 29 Vac/Vdc | -4 to 140ºF | 1000 ppm (factory set) | ± 0.3 % |