DwyerOmegaQ5-B5-Series
Q5-SIH4-50P-0-X
Smart Sensor, Silane, 0-50 ppm, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU
- 판매 가격
- 가격 문의
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 6 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Applications:Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment
Approvals:RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204)
Baud Rate Note:Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800)
Buzzer:80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones)
Cable Type:Insulated Shielded
Calibration Note:Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly
Conduit Connection:3/4 in Knockouts
Electrical Connection:Screw Terminal
Electrical Life:200,000 operations minimum at rated load
Enclosure Material Note:Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66)
Enclosure Ratings:IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0
Fuse Rating:0.75 A Polyswitch
Keypad:3 Capacitive Touch sensing keys
LED Indicators:Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3)
Mechanical Life:50 million operations
Operating Environment:Indoor use only
Operating Humidity:5 to 95% RH, non-condensing
Operating Temperature, Max:122 °F
Operating Temperature, Min:32 °F
Output Detail:Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires)
Power Consumption:8.4 VA
Sensor Type:Infrared
Series ID:Q5-B5-Series
Service Life:Electrochemical (Toxic): 2 to 3 Years, typical
Shelf Life:6 months
Storage Temperature, Max:68 °F
Storage Temperature, Min:32 °F
Supply Current:0.3 A
Tightening Torque:0.37 ft-lb (0.502 Nm) Nominal
Warm Up Time:24 Hours (Allow 24 hours before calibrating sensor after installation)
Weight:1 lb
Width:3.54 in
Wire Gauge:24 to 16 AWG
문서 및 매뉴얼