로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 80개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Applications | Approvals | Baud Rate Note | Buzzer | Cable Type | Calibration Note | Conduit Connection | Electrical Connection | Electrical Life | Enclosure Material Note | Enclosure Ratings | Fuse Rating | Keypad | LED Indicators | Mechanical Life | Operating Environment | Operating Humidity | Operating Temperature, Max | Operating Temperature, Min | Output Detail | Power Consumption | Sensor Type | Series ID | Service Life | Shelf Life | Storage Temperature, Max | Storage Temperature, Min | Supply Current | Tightening Torque | Warm Up Time | Weight | Width | Wire Gauge | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
85930-006-000가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
85930-007-000가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
85930-040-000가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-BUTAN-100L-O-X가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-C2H4-100L-O-X가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-C3H8-100L-O-X가격 문의8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-C5H12-100L-O-X가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-CH3OH-100L-O-X가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-CH4-100L-O-X가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-CL2-5P-O-X가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-CO2-5000P-O-X가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-CO2-5V-O-X가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-ETO-20P-O-X가격 문의13 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-DIESEL가격 문의8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-ETHANOL가격 문의8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-GAS가격 문의8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-HEPTANE가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-HEXANE가격 문의9 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-IPA가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG | |
B5-GENL-100L-O-X-VOC가격 문의6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment | RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) | Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) | 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones) | Insulated Shielded | Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly | 3/4 in Knockouts | Screw Terminal | 200,000 operations minimum at rated load | Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) | IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0 | 0.75 A Polyswitch | 3 Capacitive Touch sensing keys | Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3) | 50 million operations | Indoor use only | 5 to 95% RH, non-condensing | 122 °F | 32 °F | Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) | 8.4 VA | Infrared | Q5-B5-Series | Electrochemical (Toxic): 2 to 3 Years, typical | 6 months | 68 °F | 32 °F | 0.3 A | 0.37 ft-lb (0.502 Nm) Nominal | 24 Hours (Allow 24 hours before calibrating sensor after installation) | 1 lb | 3.54 in | 24 to 16 AWG |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.