DwyerOmegaOSXL-101-Series
OSXL-101-25H
Fixed Mount Thermal Imager
- 가격
- 4,706,080 원
- VAT 10%
- 470,608 원
- 총 금액
- 5,176,688 원
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 10 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Brand:OMEGA Engineering
Accuracy:± 3 °C (± 5.4 °F)
Accuracy Detail:± 2% of reading or ± 3° C whichever larger (at ambient temp of 25°C ± 2° C)
Additional Features 1:High Temperature
Alarm:2 SPST (non-voltage contactoutput)
Application Software:Requirements OS: Windows® 2000 (SP4 or later)/XPNista (Windows XP or later recommended) NET Framework 2.0 or later (required) Memory Windows 2000/XP: 1 GB recommended (512 MB or more) Windows Vista: 2 GB or more recommended CPU Windows 2000/XP: 1.5 GHz or faster recommended Windows Vista: 2 GHz or faster recommended Basic Function When the LAN settings are completed correctly between a PC and the thermal image sensor and the LAN communication is established, thermal image screen will appear; the thermal images up to 4 sensors can be displayed with this application software, and the simultaneous display for images and the individual display for each sensor can be switched. Various Settings of Sensor LAN settings/alarm settings of the sensors/emissivity setting Data Storage Image temperature data storage (temperature data/csv for 2256 pixels)/ Thermal image screen storage (JPEG) Image Processing Screen averaging/spatial smoothing/ median filter/rotation/maximum and minimum values indications Trend Graph By specifying a graph area, data can be displayed by the trend graph and the graph data can be stored by setting. (max 8 areas) Alarm Settings by the Application Software • By specifying a zone, alarms can be set (max 8 areas) • The zone alarm as set in the application software are separate and in addition to alarms set in the sensor
Capturing Mode:PLC Connection
Capturing Mode Note:PLC Connection • The temperature data is outputted row-by-row Horizontally by a command from PLC, etc
Data Interface:Ethernet
Detector Dimension:48 x 47 Pixels
Detector Type:Thermopile array
Emissivity, Max:1
Emissivity, Min:0,1
Enclosure Ratings:IP65, NEMA Type 4
Enclosure Ratings Note:NEMA 4 (IP65) (with provided exclusive cable and tripod screw)
Field of view:25° x 25°
Focus:Fixed
Frame Speed:3 fps
Frame Speed Note:3 fps (1 fps for alarm output)
Functions:Monitoring Mode The temperature data is outputted continuously by a command from the PC. Capturing Mode The temperature data is outputted row•by•row horizontally by a command from PLC, etc. Connectivity Up to 4 sensors can be connected to a PC via LAN and viewer software allows you to monitor thermal images, measuring temperature and alarms.
Housing Material:Polycarbonate
Inrush Current:Maximum 1.3A @12 Vdc (the inrush current should beconsidered for the selection of power)
Monitor Mode:Multiple Unit Connection, Single Unit Usage
Monitor Mode Note:Multiple Unit Connection (LAN) • p to 4 sensors can be connected • Monitoring and alarm outputs from sensor can be used together Single Unit Usage • Single unit can monitor 1 area and has 2 alarm outputs • When alarm goes on, the unit stores 1 image to the memory • Image saving updates every occurrence of alarm • Reading the data from host PC is possible
Mounting:Fixed Mount Thermal Imager
Object Temperature, Max:800 °C
Object Temperature, Min:100 °C
Operating Temperature, Max:50 °C
Operating Temperature, Min:-10 °C
Radius Resolution:21.8 mrad
Relative Humidity Note:10 to 80% RH (no dew condensation)
Temperature Resolution:0.5 °C
Wavelength Dimension:10 μm
Wavelength Position:Center
Weight:150 g
Weight Note:Approximately 150 g (5.2 oz) (sensor only)