DwyerOmegaMX1101-TH-Logger
MX1101
HOBO MX Bluetooth Low Energy Temperature and Humidity Data Logger with Display
- 판매 가격
- 가격 문의
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 9 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Brand:OMEGA Engineering
Accuracy Detail:Temperature Sensor Accuracy: ± 0.21°C from 0° to 50°C, Relative Humidity Accuracy: ± 2% from 20% to 80% at 25°C
Approvals:CE
Battery Size and Type:Alkaline AAA
Battery life:1 yr, typical with reading interval of 1 min
Configuration:HOBOmobile® app Android, iOS
Data Interface:Bluetooth
Data Interface Note:Mobile Device Compatibility: iOS 8.3, 8.4 & 9.0, or Android 4.4, 5.0, 5.1 and Bluetooth 4.0 or later Bluetooth Compatibility : Bluetooth 4.0 or later (Bluetooth Low Energy, Bluetooth Smart)
Display Note:LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Display Type:LCD
Enclosure Ratings:IP50
Form Factor Note:"Use the four magnets on the back of the logger case to mount it to a magnetic surface. • Attach Command strips to the back of the logger to mount it a wall or other flat surface. Double up the two Command strips so that they protrude past the magnets. • Use the double-sided tape to affix the logger to a surface. • Insert the hook-and-loop strap through the mounting loops on both sides of the logger to mount it to a curved surface, such as a pipe or tubing."
Form factor:Magnetic Surface or Insert the tie wraps
Height:0.9 in
Input Type:Internal
Length:3.34 in
Logging Modes:burst, Fixed interval
Measurement Type:Relative Humidity, Temperature
Memory Note:Approximately 60 seconds; may take longer the further the device is from the logger
Number of Measurements:2
Operating Temperature, Max:70 °C
Operating Temperature, Min:-20 °C
RH Resolution:0.0001
RH Sensor Drift:<1% Per Year
Radio Power:1 mW
Relative Humidity:1% to 95%
Relative Humidity Accuracy:± 2% RH
Response Time:Temperature: 7 hrs 30 Min, RH: 20 sec
Response Time Note:Temperature: 7:30 Minutes in air moving 1 m/s, RH: 20 seconds to 90% in airflow of 1 m/s
Restart Mode:Push button
Samples,Max:85k Samples, Interval Selectable 1 sec to 18hrs
Start Modes:At set date and time, Button Push, Immediate Start, Next Interval
Stop Modes:Button Push, When Memory is Full, At set date and time, At set Duration
Supply Power Type:Battery
Temperature Accuracy:± 0.21°C
Temperature Measurement, Max:70 °C
Temperature Measurement, Min:-20 °C
Temperature Resolution:0.024 °C
Temperature Sensor Drift:< 0.1°C Per Year
Time Accuracy:± 1 minute/month at 25°C
Transmission Range:30.5 m
Weight:1.98 oz
Width:1.44 in