DwyerOmegaCN8501-Series
CN8502RTD-DC1-DC2-C2
1/16 DIN Temperature/Process Controllers
- 판매 가격
- 가격 문의
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 10 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Brand:OMEGA Engineering
Accuracy:± 0.2 %
Accuracy Detail:± 0.2% of full scale, ± digit
CMRR:>100 dB
Cold Junction Compensation:0.05°C/°C ambient
Control Characteristics:Setpoint Limits: Limited to configured range for thermocouple and RTD; limited to scaled range Alarms: Adjustable for high/low, process or deviation Rate: 0 to 900 seconds Reset: 0 to 3600 seconds Cycle Time: 0.2 to 120 seconds Gain: 0 to 400 Gain Ratio: 0 to 2.0 (in 0.1 increments) On/Off Deadband: 1 to 100 counts Spread (Output 2): 0 to 100 counts (above setpoint) Damping: Adjustable (low, normal or high) Ramp to Setpoint: 1 to 100 minutes Autotune: Operator initiated from front panel Manual Control: Operator initiated from front panel
Control Output:2 DC Pulse
Current, Max:4 to 20 mA, 500 Ω maximum
Data Interface:RS232
Depth Behind Panel:100 mm
Display Size:9.2 mm (.36 in)
Display Type:4 Digit LED
Display Type Note:Dual LED, 4-digit, orange process display, green menu/ parameter display; 9.2 mm (0.37"), 3.5 Digit Dual Display LED
Electrical Connection:Screw Terminal
Enclosure Ratings:IP65, NEMA Type 4X
Form factor:1/16 DIN
Height:53 mm
Input Type:RTD
Input Type Note:Thermocouple Lead Resistance: 100Ω max for rated accuracy Response Time: 0.1, 1.0, or 10 s Decimal Position: Selectable
Length:18.3 mm
Measurement Type:Temperature
Measuring Range:RTD (3-wire, 100Ω Pt ): -200 to 850°C, RTD (3-wire, 100Ω Pt ): -128.8 to 232.2°C
Memory Backup:Solid State
Number of Control Outputs:2
Number of Inputs:1
Operating Temperature, Max:55 °C
Operating Temperature, Min:0 °C
Output Detail:DC Pulse, DC Pulse;Output #1: Reverse acting (heating) Output #2: Direct acting (cooling) Mechanical Relay: Rated 5A @ 120 Vac, 3A @ 240 Vac Current: 4 to 20 mA, 500 Ω maximum Voltage: 20 Vdc pulse, 1 kΩ minimum load Triac: SSR, 120/240 Vac, zero voltage switched rated 1A continuous, 10 A surge @ 25°C ;Alarm Output-Optically isolated triac rated 1A, 120/240 Vac @ 25°C
Output Signal:DC Pulse
Ramp and Soak:Ramp to SP
Relative Humidity:90% RH, non-condensing
Repeatability:± 1 count
Resolution:1°C
Response Time:0.1, 1.0, or 10 s
Sampling Rate:10 Hz (10 updates/second)
Series Mode Rejection:>70 dB
Setpoint Resolution:1 count/0.1 count
Supply Power Note:115 to 230 Vac ± 10%, 50/60 Hz; 115 to 300 Vdc ± 10% (auto-polarity), optional 24 Vdc/Vac Output Voltage: 20 Vdc pulse, 1 kΩ minimum load
Supply Power Type:AC
Supply Voltage:115 to 230 Vac
Temperature Stability:5 μV/°C maximum; 3 μV/°C
Thermocouple Lead Resistance, Max:100 Ω
Weight:0.25 kg
Width:53 mm