Industrial Thermocouple Handheld Calibrator

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 9 weeks리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Brand:OMEGA Engineering
Additional Features 1:Read and Source Signals
Auto Off:20 min
Auto Off Note:20 minute no key pressed Auto Off. Feature can be disabled
Battery Indication:4 stage battery charge indication
Battery life:500 hr
Cold Junction Error:± 0.15 °C
Common Mode Voltage:42 V
Common Mode Voltage (CJC error), Max:1 V
Common Mode Voltage Note:42 V peak to earth; 1 V p-p between T1 and T2
Compliance:CE, Mil-PRF-28800F Class 2, REACH, RoHS 2
Dimensions (CJC error):7.6 L x 3.3 W x 1.1 H in
Display Backlight:Four (4) LED Backlight with 30-second timeout
Display Measuring Units:°C, °F, mV
Display Resolution:0.01°
Display Resolution (CJC error):0.1°
Display Type:Backlit LCD
Display Type Note:5-DIGIT AUTO-RESOLUTION (0.1/0.01) WITH BACKLIGHT AND FUNCTION ANNUNCIATORS Two (2) rows of Five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth
EMC Standard:Class 2, EN 61326, MIL-PRF-28800F
ESD Standard:IEC 61326 Criterion B
Electrical Connection:Miniature Female Thermocouple Connector
Electrical Safety:IEC-61010
Height:28 mm
Input Current:± 50 nA
Internal Preset Storage:20 user defined presets available
Keypad:12 Switches
Length:193 mm
Low Resistance Load:Less than 5µV change in output with a 100KΩ resistance
Millivolt Range:-15 to 85 mV
Operating Environment:Altitude: 0 to 4600 m ; 0 to 15,092 ft(CJC Error) Vibration: Random 10 – 500 Hz; 0.03 g2/Hz(CJC Error) Shock: 30g Half Sine Drop: 4 Drops from 1 m to Concrete
Operating Temperature Note:Operating Temperature(CJC error): -4 to 131°F
Operating Temperature, Max:55 °C
Operating Temperature, Min:-20 °C
Power Cycle Configuration Retention:Instrument retains: Sensor Type, Temperature Unit Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Probe Offset Uncertainty:Resolution 0.1 °C/°F
Reading Rate:3/sec
Reading Rate Note:3/sec. for Readings and TREND indicators
Relative Humidity Note:<10 °C (50 °F): Non-condensing 10 to 30 °C (50 to 86 °F): 5 to 95% RH 30 to 40 °C (86 to 104 °F): 5 to 85% RH 40°C to 55°C (104 to 131 °F): 5 to 60% RH
Relative Humidity, Max:0.95
Relative Humidity, Min:5%
Resolution Note:0.01°C UP TO 999.99°C AND 0.1°C ≥ 1000°C
Resolution, Max:999.99 °C
Resolution, Min:0.01 °C
Sanitation:NSF, ANSI/3-1 14159-2
Statistics:Average, Maximum, Minimum, Range, Standard Deviation
Storage Temperature Note:Storage Temperature(CJC error): -59.8 to 159.8°F
Storage Temperature, Max:71 °C
Storage Temperature, Min:-51 °C
Supply Voltage:4.5 Vdc
Temperature Coefficient:For specification variances due to ambient operating temperature, see the Expanded Instrument Uncertainty charts in Appendix B of this manual. For ambient operating temperatures not shown in Appendix B, accuracies shall be interpolated linearly.
Thermocouple Type:J, K, T, E
Weight:362.9 g
Weight (CJC error):12.8 oz (including batteries)
Weight Note:362.9g (including batteries)
Width:84 mm