
DwyerOmegaAM-2250-Controller
AM-2250
MULTI-VARIABLE CONTROLLER, ph, ORP, CONT
- 가격
- 2,367,130 원
- VAT 10%
- 236,713 원
- 총 금액
- 2,603,843 원
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 2 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Brand:OMEGA Engineering
Additional Features 1:PID Control, Sensors Sold Separately
Calibration Note:pH Calibration modes: Automatic or Manual 2 or 3 points; ORP Calibration modes: Manual 1 point; Conductivity Calibration modes: Up to 16 points; Flow Calibration modes: K factor input
Compliance:ETL
Compliance Note:ETL (US and Canada) and CE pending
Conductivity Measurement:0.055 to 500,000 µS/cm
Cutout Dimensions:5.4 x 5.4 in
Display Type:LCD
Electrical Output:4 to 20 mA
Enclosure Ratings:NEMA Type 4X
Flow Indication Note:0 to 999 in any units
Height:5.5 in
Input Range Note:pH Sensor Input: -600 to +600 mV; ORP Sensor Input: -999 to +999 mV; Conductivity Sensor Input: 0 to 9999 Ω; Flow Sensor Input: 0 to 2000 Hz
Length:5 in
Mounting Orientation:Panel Mount, Wall Mount
Number of Relays:3
ORP Measurement Range:-1000 to +1000 mV
Operating Humidity:0 to 90% RH
Operating Temperature, Max:120 °C
Operating Temperature, Min:-20 °C
Output Detail:Two 4-20 mA outputs, Scalable 4-20mA with PID (Process), Scalable 4-20mA (Process or Temperature), Optically isolated. Max Load - 800 Ω
PH Measurement Range:0 to 14.00 pH
Power Consumption:0.2 A @ 115 Vac or 15 W
Process Temperature, Max:-20 °C
Process Temperature, Min:70 °C
Relay Note:3 Dry contact relay with snubber circuit, 10A @ 120/240 VAC or 8A @ 30 VDC (Resistive Load), 5A @ 120/240 VAC or 4A @30 VDC (Inductive load) Relay Modes: Rising/Falling/In Range. Options: Relay Delay, Cycle, Overfeed Timer, Override, One relay can be triggered by temperature or flow totalizer.
Relay Output:Dry contact relay
Sensing Element:100/1000 Ω RTD, 300/3K Ω NTC or none
Sensing Element Note:PH, ORP, Conductivity: 100, 1000 Ω, RTD 300, 3K Ω NTC or none
Sensor Type Note:pH Sensor: 6-Wire Differential or Combination; ORP Sensor: 6-Wire Differential or Combination; Conductivity Sensor: 4-Wire contacting : Any cell constant between 0.01 and 100; Flow Sensor: Pulse output: Paddle-wheel, Magmete
Supply Voltage:120/240 Vac
Temperature Compensation:Automatic: pH ;Automatic or Manual: Conductivity ;Display temperature: ORP ;Display Flow Totalizer: Flow
Temperature Measurement Note:pH, ORP, Conductivity : -20 to 120 °C, Flow : Flow Totalizer 0 to 999 in any units
Weight:2 lb
Width:5.5 in
