DwyerOmegaSIL2-capable-Oxygen-Analyzer
06-912
SILO2 Oxygen analyzer with Solid State-Electrochemical Sensor, 0 to 25% range, 2 inch Tri-clamp connection, ±0.03% accuracy. SIL2-capable system designed for inertization in hazardous industrial environments.
- 판매 가격
- 가격 문의
수량
재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.
무료 배송 10만원 이상
납기: 9 weeks리드타임은 상황에 따라 달라질 수 있습니다.
연구비카드 사용가능
실시간 문의하기제품 사양
Accuracy:± 0.01 %
Accuracy Detail:+/- 0.02 % @ 1 %, +/- 0.01 % @ 0.1 %
Applications:Chemical Refineries, Gases, Industrial and Manufacturing, Laboratories, Pharmaceutical
Cable Length:5 m
Calibration Interval:6 to 12 months
Connection Note:Intrinsically Safe Connection: Voltage Uo = 6 V DC Current intensity Io = 0.2 mA Power Po = 0.3 mW Max. outer inductivity Lo = 1000 mH Max. outer capacity Co = 10 μF
Control Output:Alarm
Data Interface:RS485
Display Type:LCD
Electrical Output:4 to 20 mA
Enclosure Material:PBT
Enclosure Ratings:IP20
Flow Rate Note:100 to 500 ml/min (250 ml/min optimal) in a vented atmosphere
Gas Measurement Range:0 to 25 %
Indicator Type:LCD and LED alerts on analyzer
Length:70 mm
Lifetime:up to 24 mo
Operating Humidity:0 to 95% RH, non-condensing
Operating Temperature, Max:50 °C
Operating Temperature, Min:-20 °C
Output Detail:Relay Contact Outputs RL1 / RL2 / Alarm: Switching power max.: 62.5 V A resp max. 30 W Switching voltage: Um 125 V AC/110 V DC Min. current 10 uA DC Min. voltage 10 mV DC According to IEC 947-5-1 resp. EN 60947 Transistor Output (DO): Switching parameters: < 28 V @ < 50 mA
Power Consumption:1.5 W
Process Connection Size:2 in
Process Connection Type:Tri-Clamp
Relay Output:1 A @ 30 Vdc, 0.5 A @ 125 Vac
Resolution:0.01%
Response Time:<20 seconds, typically 12 seconds
Sensitivity:0.02 % +/- 0.01
Series ID:SIL2-capable-Oxygen-Analyzer
Shelf Life:12 months
Supply Power Type:DC
Supply Voltage:24 Vdc
Width:100 mm
문서 및 매뉴얼
SIL2-capable-Oxygen-Analyzer Data Sheet
PDF
NT_SILO2OxygenAnalyzerSafetyManual_NT-SM-2101-EN-1-2-08-055.pdf - nt_silo2oxygenanalyzersafetymanual_nt_sm_2101_en_1_2_08_055_pdf_ntron_pdf
PDF
NT_SILO2OxygenAnalyzerusermanual_06-183-rev1-7.pdf - nt_silo2oxygenanalyzerusermanual_06_183_rev1_7_pdf_ntron_pdf
PDF