로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

고정밀, 밀폐형 압력 변환기
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 399개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Brand | Accuracy | Accuracy Class | Additional Features 1 | Burst Pressure | Burst Pressure Note | Compensated Temperature, Max | Compensated Temperature, Min | Electrical Connection | Electrical Connection Note | Electrical Output | Electrical Output Note | Hysteresis | Linearity Error | Linearity Note | Materials, Wetted | Mating Connector | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Operating Temperature, Max | Operating Temperature, Min | Output Signal | Process Connection Size | Process Connection Type | Proof Pressure | Proof Pressure Note | Repeatability Error | Sensing Element | Sensing Element Note | Shunt Calibration Value | Supply Voltage | Thermal Effect on Span error, Max | Thermal Effect on Zero error, Max | Weight | Zero/Balance Error | Input Resistance | Output Resistance | Series ID | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PX01C6-1KGI가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
PX01C6-200GI가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
PX01D1-050AI가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
PX01C0-002A10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-002G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-010A5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-010G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-020A10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-020A5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-050A10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-050A5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-050G10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-1.5KA10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-100G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-150G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-1KA5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-200G10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-200G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-2KG10E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 | |
PX01C0-500G5E가격 문의28 weeks리드타임은 상황에 따라 달라질 수 있습니다. | - | - | < 0.1% | None | 3x Full Scale | 300% of rated pressure | 71 °C | 16 °C | - | - | - | - | 0.05% FSO | - | - | 17-4 Stainless Steel | MIL-26482-I 10-6S | - | - | 0 bar | - | - | - | - | - | 150% Full Scale | 150% of rated pressure | ± 0.05% FSO | 4-active-arm Strain Gauge Bridge | 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber | Value Specified on calibration sheet | - | - | - | - | - | - | - | PX01 |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.