| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Battery Size and Type | Battery life | Cable Length | Calibration | Compensated Temperature, Max | Compensated Temperature, Min | Connection Location | Data Interface | Dial Dia | Display Size | Display Type | Display Type Note | EMC Standard | Electrical Connection Note | Electrical Output | Electrical Output Note | Enclosure | Enclosure Material | Enclosure Ratings | Enclosure Ratings Note | Fill Fluid | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Digits | Operating Temperature, Max | Operating Temperature, Min | Overload Protection | Pressure Accuracy | Pressure Cycles | Process Connection Note | Process Connection Size | Process Connection Type | Proof Pressure | Sample Display Rate Note | Sensor Dimension Note | Sensor Type | Settable Parameters | Software Settings | Span Setting | Thermal Effects | Weight | Wireless Option Specifications | Zero/Balance Error | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPGM409S15-170HG-W가격 문의 | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 170 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | Wireless | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-070HG-W가격 문의 | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 70 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | Wireless | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-007BG-W가격 문의 | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 7 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | Wireless | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-010BG-W가격 문의 | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 10 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | Wireless | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-17.5BG2,635,850 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 17.5 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-025HCG3,131,630 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Compound Gauge | 25 mBar | -25 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-001BCG2,974,700 원20 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Compound Gauge | 1 bar | -1 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S20-025HG가격 문의13 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 2 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 25 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S20-010BG가격 문의20 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 2 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 10 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S20-010BA가격 문의20 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 2 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Absolute | 10 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S20-007BG가격 문의21 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 2 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 7 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-350HA2,974,700 원11 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Absolute | 350 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-3.5BG2,635,850 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 3.5 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-070HG2,815,510 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 70 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-170HG2,815,510 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 170 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-025HG2,815,510 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 25 mBar | 0 mBar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-010BG2,635,850 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 10 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-007BG2,635,850 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 7 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-002BA2,815,510 원18 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Absolute | 2 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | |
DPGM409S15-001BG2,635,850 원20 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined) ,Analog Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m); Long-Term Stability: ± 0.1 % | 3.6V Li-ion | 4 yr | 2.7 m | 5-Pt NIST traceable calibration with zero and span values, calibrated in horizontal direction (compound gauge models calibrated in positive direction only). calibrated in horizontal direction | 85 °C | -4 °C | Lower | USB | 1.5 in | 115 x 89 x 74 mm | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height | EN 61326 | Cable Material: Ferrite Core | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required) Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | Electropolished | 316 Stainless Steel, ABS | IP65 | NEMA 4X (IP65) depending upon electrical termination Enclosure Environmental Rating : Weatherproof, NEMA 4X (IP65) | NEOBEE M5 food grade | Gauge | 1 bar | 0 bar | 4 | 115 °C | -15 °C | 6 x rated pressure to a maximum of 138 bar (not in clamp) | ± 0.08 % | 2,50,000 Min | Pressure Limits: Up to 580 psi; Pressure Rating: 1½" and 2" Tri-Grip™ fitting (compatible the Tri-Clamp®): 40 bar using suitable clamp | 1 1/2 in | Tri-Grip | 400% Full Scale | User selectable from 0.35 to 30 seconds (preset to 1/second) | 72 to 89 mm L (2.8 to 3.5") below display | N/A | Backlight, Min/Max, Zero/Clear | Update Rate: 4 options; 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable High and Low alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): channel number, Transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: "_ _ _ _" | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) | Compensated Temperature Range: ≤350 mb: 4.4 to 60°C, >350 mb: -4 to 85°C ; Zero & Span shift over Compensated Range: ≤170 mb: Z: 1.00% S: 0.70% , 350 mb: Z: 0.80% S: 0.50% , > 350 mb: Z: 0.50% S: 0.50% ; 550 & 880HB Barometric Range: Z: 0.90% S: 0.50% | 900 g | Transmit Sample Rate: User programmable from 1 sample/2 minute to 1 sample/2 seconds Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | ±0.5% FS typical ±1% maximum (for ranges ≤170 mb ±1% Typical ±2% maximum) |