| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Battery Size and Type | Battery life | Burst Pressure | Cable Length | Compliance | Data Interface | Display Size | Display Type | Display Type Note | Electrical Output | Electrical Output Note | Enclosure Material | Enclosure Ratings | Materials, Wetted | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Batteries | Number of Digits | Output Signal | Pressure Accuracy | Pressure Cycles | Process Connection Size | Process Connection Type | Process Temperature, Max | Process Temperature, Min | Proof Pressure | Sample Display Rate Note | Sample/Display Rate | Sensor Dimension Note | Settable Parameters | Software Compatibility | Software Settings | Stability | Supply Power Type | Supply Voltage | Thermal Effects | Thermal Span Effect | Thermal Zero Effect | Weight | Weight Note | Wireless Band | Wireless Option Specifications | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPGM409-025HCG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 1015 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 25 mBar | -25 mBar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-001BCG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 1 bar | -1 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-350BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 350 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-175BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 175 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-3.5BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 3.5 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-100BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 100 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-050BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 50 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-010BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 10 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-007BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 7 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-007BA-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 5800 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Absolute | 7 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-002BG-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 2 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-002BA-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 5800 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Absolute | 2 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-001BV-W가격 문의 | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Vacuum | -1 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-170HCG2,714,760 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 1015 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 170 mBar | -170 mBar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-350HCG2,530,670 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 1015 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 350 mBar | -350 mBar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-17.5BG가격 문의9 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Gauge | 17.5 bar | 0 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-1100HB2,714,760 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 5800 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Barometric | 1100 hPa | 0 hPa | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-070HCG2,714,760 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 1015 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 70 mBar | -70 mBar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-025HCG2,714,760 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 1015 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 25 mBar | -25 mBar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. | |
DPGM409-001BCG2,530,670 원20 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | ± 0.08% BSL (0.15% max in 10V/m RF field) (compound gauge calibrated in positive direction only) | 3.6V Li-ion | 9 mo | 2900 psi Maximum | 2.7 m | CE | USB | 115 mm (4.5 in) | LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -350 to 350 mb = 0 to 10 Vdc. | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 316 Stainless Steel | Compound Gauge | 1 bar | -1 bar | 1 | 4 | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | BSPP Male | 66 °C | -18 °C | 10x Full Scale | User selectable from 0.25 to 10 sec. (preset to 1/sec) | 0.25 to 10 sec | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Requires Windows® 7 (32 bit); XP or Vista | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Overrange Indication: “_ _ _ _” | ± 0.1% FS typical | Battery | 3.6 Vdc | Zero Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb: ± 0.5% spanSpan Shift: Ranges >350 mb: ± 0.3% spanRanges ≤350 mb psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (32 oz) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included, (replacement battery BATT-C-3.6V) Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. |