로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

고정밀 디지털 압력 게이지, 출력 기능 및 NEMA 4X 케이스 포함
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 79개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Battery Size and Type | Battery life | Cable Length | Compliance | Connection Location | Data Interface | Data Interface Note | Display Segment Height | Display Type | Display Type Note | Electrical Output | Electrical Output Note | Enclosure Material | Enclosure Ratings | Isolation between Case and Output Terminations, Min | Materials, Wetted | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Batteries | Number of Digits | Operating Temperature, Max | Operating Temperature, Min | Output Signal | Pressure Accuracy | Pressure Cycles | Process Connection Size | Process Connection Type | Sample Display Rate Note | Sample/Display Rate | Sensor Dimension Note | Settable Parameters | Software Settings | Storage Temperature, Max | Storage Temperature, Min | Supply Power Note | Supply Power Type | Thermal Effects | Thermal Span Effect | Thermal Zero Effect | Weight | Weight Note | Wireless Band | Wireless Option Specifications | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPG409-3.5KG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 3500 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-5.0KG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 5000 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-2.5KG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 2500 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-2.5CG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Compound Gauge | 2.5 psi | -2.5 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-005CG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Compound Gauge | 5 psi | -5 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-1.5KG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 1500 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-750G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 750 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-750A-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Absolute | 750 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-500G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 500 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-250G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 250 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-500A-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Absolute | 500 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-250A-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Absolute | 250 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-2.5G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 2.5 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-16HB-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Barometric | 1100 mBar | 550 mBar | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-150A-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Absolute | 150 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-150G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 150 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-10WV-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Vacuum | -10 inH₂O | 0 inH₂O | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-10WG-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 10 inH₂O | 0 inH₂O | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-100G-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Gauge | 100 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-100A-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only) | Alkaline | 9 mo | 2.7 m | CE | Lower | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 100MΩ @ 50 Vdc | 316 Stainless Steel | Absolute | 100 psi | 0 psi | 2 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | User selectable from 0.38 to 30 sec. (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 x 3.5") below display | Backlight, Min, Max, Zero, Clear | Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” | 82 °C | -40 °C | Battery Note:Two 1.5 V alkaline (C cell) included | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span | ± 0.3% | ± 0.3% | 900 g | 900 g (2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.