| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Auto-Shutoff | Battery Size and Type | Battery life | Calibration | Calibration Note | Connection Location | Dial Dia | Display Type | Display Type Note | Keypad Functions | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Batteries | Number of Digits | Operating Temperature, Max | Operating Temperature, Min | Pressure Accuracy | Process Connection Size | Process Connection Type | Storage Temperature, Max | Storage Temperature, Min | Supply Power Type | Thermal Effects | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPG7025-VAC/302,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 30 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-VAC/152,789,120 원11 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 15 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-VAC/303,244,650 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 30 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7000-VAC/303,661,370 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 30 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.05 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-VAC/153,244,650 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 15 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7000-VAC/153,549,170 원14 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Compound Gauge | 15 psi | -15 psi | 3 | 5 | 63 °C | -18 °C | ± 0.05 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-VAC2,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Vacuum | -15 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-5002,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 500 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-600가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 600 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-3002,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 300 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-2002,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 200 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7025-1002,789,120 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 100 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.25 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-50A가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Absolute | 50 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-VAC3,244,650 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Vacuum | -15 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-5003,244,650 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 500 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-3003,244,650 원8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 300 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-1003,244,650 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 100 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7010-2003,244,650 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 200 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.1 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7000-VAC3,568,800 원10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Vacuum | -15 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.05 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification | |
DPG7000-3003,568,800 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Total error band (TEB) including hysteresis, linearity, repeatablilty and temperature from -18 to 66°C (0 to 150°F) | Five Options: Never, 2, 5, 15, 30 min | Alkaline AAA | 1000 hr | Zero and Span (password protected) | 10 point individual calibration chart, standard for DPG7000; optional for DPG7010 and DPG7025 models | Lower | 85 mm | LCD | Type: LCD, with bar graph; backlight standard Display Digits: 5, 99,999 counts Character Height: 16.7 mm (0.66") Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 Update Rate: Four Options; 10x/sec, 5x/sec, 2x/sec, 1x/sec Dampening: Five Options; None, average 2, 4, 6, 8 readings Language: Seven Languages; English, Spanish, French, Italian, German, Portuguese, Dutch Backlight: Five Options; On/off, 10 sec., 30 sec., 1 min., 5 min. Zero Disable: Allows for disabling of Zero button Contrast: Seven available options Disable: Allows for “lock-out” of CONFIG options | On/Off: Manually turns unit on and off Backlight: Manually turns backlight on and off Minimum/Maximum: Stores minimum and maximum values when displayed Zero/Clear: Zeros display or clears minimum and maximum values when displayed Enter: Selects items in configuration menu Config: Configuration mode; allows scrolling through configuration menus to select available options. | Gauge | 300 psi | 0 psi | 3 | 5 | 63 °C | -18 °C | ± 0.05 % | 1/4 in | NPT Male | 82 °C | -40 °C | Battery | -18 to 63°C (0 to 150°F); included in accuracy specification |