로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

교류/직류 전원, 출력 및 알람 기능이 있는 디지털 압력 게이지
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 11개의 상품
| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Alarm Indication | Cable Length | Control Output | Controls and Location | Electrical Connection | Electrical Output Note | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Digits | Pressure Accuracy | Process Connection Size | Process Connection Type | Response Time | Sensor Type | Supply Power Note | Supply Voltage | Wire Gauge | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPG1000ADA-300G-1N1,328,120 원8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 300 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-500G-1N1,328,120 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 500 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-200G-1N1,320,820 원9 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 200 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-100G-1N1,328,120 원9 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 100 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-3KG-1N1,382,850 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 3000 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-60G-1N가격 문의9 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 60 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-30G-1N1,362,770 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 30 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-30A-1N1,401,260 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Absolute | 30 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-1KG-1N1,320,820 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 1000 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-15A-1N1,320,820 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Absolute | 15 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG | |
DPG1000ADA-15G-1N1,362,770 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 0.1% to 0.25% | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability); Hysteresis: 1% of FSO, standard | Red LED, Green LED | 0.9 m | Hi/Lo Normal Action | Display zero/ span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers | Cable | Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive; Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation | Gauge | 15 psi | 0 psi | 4 | ± 0.25 % | 1/4 in | NPT Male | 100 ms | Precision oil-filled silicon | Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS) | 8 to 24 Vac, 9 to 32 Vdc | 22 AWG |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.