로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

차동형 고정밀 디지털 압력 게이지(출력 기능 포함)
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 26개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Brand | Accuracy Class | Accuracy Detail | Battery Size and Type | Battery life | Cable Length | Compliance | Data Interface | Data Interface Note | Display Segment Height | Display Type | Display Type Note | Electrical Output | Electrical Output Note | Enclosure Material | Enclosure Ratings | Hi-Side Containment Pressure | Isolation between Case and Output Terminations, Min | Line/Static Pressure | Line/Static Pressure Note | Materials, Wetted | Measurement Pressure Type | Measurement Pressure, Max | Measurement Pressure, Min | Number of Batteries | Number of Digits | Operating Temperature, Max | Operating Temperature, Min | Output Signal | Pressure Accuracy | Pressure Cycles | Process Connection Size | Process Connection Type | Proof Pressure | Sample Display Rate Note | Sample/Display Rate | Sensor Dimension Note | Settable Parameters | Software Settings | Stability | Storage Temperature, Max | Storage Temperature, Min | Supply Power Note | Supply Power Type | Thermal Effects | Thermal Span Effect | Thermal Zero Effect | Weight | Weight Note | Wireless Band | Wireless Option Specifications | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPG409-750DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 750 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-500DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 500 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-250DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 250 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-2.5DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 2.5 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-150DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 150 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-100DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 100 psi | 2 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-10WDWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 10 inH₂O | 0 inH₂O | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 10x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 1% | ± 1% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-050DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 50 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-030DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 30 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-015DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 15 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-005DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 5 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-1KDWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 1000 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 3x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-001DWU-W가격 문의 | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 1 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | Nema 4X Enclosure, Backlit display | 1/4 in | NPT Male | 6x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 1% | ± 1% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | 2.4 GHz | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-750DWU3,198,270 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 750 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-500DWU3,300,030 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 500 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-250DWU3,681,470 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 250 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-2.5DWU3,349,040 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 2.5 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-150DWU3,300,030 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 150 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-10WDWU3,373,150 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 1000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 10 inH₂O | 0 inH₂O | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 10x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 1% | ± 1% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level | |
DPG409-050DWU3,417,400 원7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | < 0.1% | Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL | 3.6V Li-ion | 9 mo | 2.7 m | CE | USB | USB connection for set-up, cable included | 25 mm | 4 Digit LCD | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. | 4 to 20 mA | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Note: Analog output is independently scalable Set jumper to select current or voltage. Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA | 316 Stainless Steel | IP65, NEMA Type 4X, Weatherproof | 3000 psi | 100MΩ @ 50 Vdc | 500 psi | 500 psi maximum applied to both sides simultaneously | 316 Stainless Steel | Differential | 50 psi | 0 psi | 1 | 4 | 66 °C | -18 °C | Current, Voltage | ± 0.08 % | 1 million minimum | 1/4 in | NPT Male | 4x Full Scale | Sample/Display Rate: User selectable from 0.38 to 30 sec (preset to 1/sec) | 0.38 to 30 seconds | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3. Weatherproof, NEMA 4X (IP65) 1") wide | Backlight, Min, Max, Zero, Clear | (USB connection is for set-up only) Note: Because of transmission frequency regulations, wireless models may only be used in the US, Canada and Europe. Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and span Overrange Indication: “_ _ _ _” | Long Term Stability (1-Yr.): ± 0.1% FS typical | 82 °C | -40 °C | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) | Battery | Thermal Effects (Over Operating Range): Zero Balance: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span Span Setting: Ranges 10 inH2O to 1 psi: ± 1% span Ranges >1 psi: ± 0.5% span | ± 0.5% | ± 0.5% | 1 kg | 1 kg (2.2 lb) Typical depending upon configuration | None | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.