로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

다중 매개변수 입력 송신기
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 2개의 상품
| 제품 번호 / 가격 | Brand | Accuracy | Accuracy Detail | Additional Features 1 | Altitude,Max | Conductivity Measurement | Control Characteristics | Control Mode | Display Measuring Units | Display Note | Display Type | Display Type Note | Electrical Connection | Electrical Output | Enclosure Material | Enclosure Ratings | Flow Indication Note | Form factor | Frequency | Input Note | Input Type | Input Type Note | Keypad | LED Indicators | Measurement Type | Mounting | Mounting Orientation | Number of Channels | ORP Measurement Range | Output Detail | Over-Voltage Protection | PH Measurement Range | Relative Humidity | Repeatability | Resolution | Sensor Voltage | Storage Temperature, Max | Storage Temperature, Min | Supply Power Note | Supply Voltage | Update Rate | Weight | Wire Gauge | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DPU911,114,330 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.5 % | ± 0.5% or reading maximum error @ 25°C (77ºF) | Field Mount, Sensors | 4000 m | 0.0000 to 99999 μS | Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s | N/A | kΩ, MΩ, ms, ppb, ppm, μS | LCD Contrast: 5 settings | Backlit LCD | Backlit, 7 and 14-segment LCD | Screw Terminal | 4 to 20 mA | PBT | IP65, NEMA Type 4X | Flow Rate: -9999 to 99999 units per second, minute, hour or day Totalizer: 0.00 to 99999999 units (program lockout or resettable) | 1/4 DIN | 0.5 to 1500 Hz | Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input | Pulse, S3L | Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 | 4 buttons, injection-molded silicone rubber seal | “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator | Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch | Specified to Omega field mount junction boxes | Field Mount | 1 | -1999 to 1999.9 mV | 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum) | 48 V transient protection device current limiting for circuit protection and reverse-voltage protection | 0 to 15 pH | 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount | ±0.2% of reading | 1 μS | 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected | 70 °C | -15 °C | DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc | 10.8 to 35.2 Vdc | 1 sec | 0.63 kg | 14 AWG | |
DPU91P가격 문의 | OMEGA Engineering | ± 0.5 % | ± 0.5% or reading maximum error @ 25°C (77ºF) | Field Mount, Sensors | 4000 m | 0.0000 to 99999 μS | Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s | N/A | kΩ, MΩ, ms, ppb, ppm, μS | LCD Contrast: 5 settings | Backlit LCD | Backlit, 7 and 14-segment LCD | Screw Terminal | 4 to 20 mA | PBT | IP65, NEMA Type 4X | Flow Rate: -9999 to 99999 units per second, minute, hour or day Totalizer: 0.00 to 99999999 units (program lockout or resettable) | 1/4 DIN | 0.5 to 1500 Hz | Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input | Pulse, S3L | Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 | 4 buttons, injection-molded silicone rubber seal | “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator | Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch | Specified to Omega field mount junction boxes | Panel Mount | 1 | -1999 to 1999.9 mV | 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum) | 48 V transient protection device current limiting for circuit protection and reverse-voltage protection | 0 to 15 pH | 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount | ±0.2% of reading | 1 μS | 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected | 70 °C | -15 °C | DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc | 10.8 to 35.2 Vdc | 1 sec | 0.63 kg | 14 AWG |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.