로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

20가지 이상의 가스 선택 기능을 갖춘 질량 유량 컨트롤러
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 67개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Brand | Accuracy | Accuracy Detail | Additional Features 1 | Calibration | Data Interface | Display Type | Electrical Connection | Electrical Output | Excess Flow Rate | Height | Humidity Range | Input Control Signal | Materials, Wetted | Measurement Pressure, Min | Media Compatibility | Operating Pressure Note | Operating Pressure, Max | Operating Pressure, Min | Operating Temperature, Max | Operating Temperature, Min | Output Signal | Process Connection Size | Process Connection Type | Repeatability | Response Time | Span Shift | Supply Current | Supply Voltage | Turndown Ratio | Volumetric Flow Rate, Max | Volumetric Flow Rate, Min | Width | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FMA-2623A-VOL가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1 1/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 750 mA | 24 to 30 Vdc | 200:1 | 3000 SLM | 0.0025 SCCM, 15 SLM | 1.1 in | |
FMA-2622A-VOL가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 3/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 750 mA | 24 to 30 Vdc | 200:1 | 2000 SLM | 0.0025 SCCM, 10 SLM | 1.1 in | |
FMA-2620A-VOL가격 문의4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 1 SLM | 0.0025 SCCM, 0.005 SLM | 1.1 in | |
FMA-2619A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 500 SCCM | 2.5 SCCM | 1.1 in | |
FMA-2618A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 200 SCCM | 1 SCCM | 1.1 in | |
FMA-2617A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 100 SCCM | 0.5 SCCM | 1.1 in | |
FMA-2616A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | #10 | UNF Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 20 SCCM | 0.1 SCCM | 1.1 in | |
FMA-2614A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % | ± (0.8% of reading + 0.2%FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | #10 | UNF Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 2 SCCM | 0.01 SCCM | 1.1 in | |
FMA-2615A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % | ± (0.8% of reading + 0.2%FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | #10 | UNF Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 5 SCCM | 0.025 SCCM | 1.1 in | |
FMA-2613A-VOL가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 3/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 1000 SLM | 0.0025 SCCM, 5 SLM | 1.1 in | |
FMA-2612A-VOL가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 3/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 500 SLM | 0.0025 SCCM, 2.5 SLM | 1.1 in | |
FMA-2611A-VOL가격 문의12 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/2 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 250 SLM | 0.0025 SCCM, 1.25 SLM | 1.1 in | |
FMA-2610A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 100 SLM | 0.0025 SCCM, 0.5 SLM | 1.1 in | |
FMA-2609A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/4 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 50 SLM | 0.0025 SCCM, 0.25 SLM | 1.1 in | |
FMA-2608A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 20 SLM | 0.0025 SCCM, 0.1 SLM | 1.1 in | |
FMA-2606A-VOL가격 문의8 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 5 SLM | 0.0025 SCCM, 0.025 SLM | 1.1 in | |
FMA-2607A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 10 SLM | 0.0025 SCCM, 0.05 SLM | 1.1 in | |
FMA-2605A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | 1/8 in | NPT Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 2 SLM | 0.0025 SCCM, 0.01 SLM | 1.1 in | |
FMA-2603A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | #10 | UNF Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 10 SCCM | 0.05 SCCM | 1.1 in | |
FMA-2604A-VOL가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | ± 0.8 % (± 0.6 % for 10 SCCM to 20 SLM) | ± (0.8% of rdg + 0.2% FS) or ± (0.6% of rdg + 0.1% FS) | Power Supply Included | NIST Certificate | RS232 | LCD | 8-pin mini DIN | 0 to 5 V | 2.4% FS | 3.9 in | 0 to 100% RH non-condensing | 0 to 5 Vdc | Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel | 5 psi | Air, Gases, Nitrogen, Oxygen | 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig | 15 psi | 0 psi | 50 °C | 0 °C | Voltage | #10 | UNF Female | ± 0.2% | 100 ms | 0.02% FS/°C/atm | 250 mA | 12 to 30 Vdc | 200:1 | 50 SCCM | 0.25 SCCM | 1.1 in |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.