로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 7개의 상품
| 제품 번호 / 가격 | Accuracy Detail | Calibration Note | Compensated Temperature, Max | Compensated Temperature, Min | Compliance Note | Electrical Connection | Electrical Output | Enclosure Ratings | Factory Setting | Flow Rate Note | Galvanic Isolation | Housing Material | Load Resistance | Measurement Type | Number of Wires | Operating Pressure, Max | Operating Temperature, Max | Operating Temperature, Min | Process Connection Type | Series ID | Storage Temperature, Max | Storage Temperature, Min | Supply Current | Supply Voltage | Temperature Measurement Range | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PUR-2W-M12-BA가격 문의10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-2W-M12-CA가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-TX-2W-AA가격 문의10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-TX-2W-BA가격 문의10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-TX-2W-CA가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-TX-3W-BA가격 문의10 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C | |
PUR-TX-3W-CA가격 문의7 weeks리드타임은 상황에 따라 달라질 수 있습니다. | ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp); ±2 °C from -60 to -100 °Cdp (±3.6 °C from -76 to -148 °Fdp); ±4 °C from -100 to -120 °Cdp (±7.2 °C from -148 to -184 °Fdp (extrapolated) | Traceable 7-point calibration certificate | 50 °C | -20 °C | ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: Ex ia IIC T4 Ga (-20 to +70 °C) TR CU: 0Ex ia IIC T4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C | M12 5 pin Male | 4 to 20 mA | IP65 | Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion | FD0-CS-EX1.50P, KFD0-CS-EX2.50P, KFD2-STC4-EX1.H | 316 Stainless Steel | Max 250 Ω @ 14 V (500 Ω @ 24 V) | Dew point, Moisture | 2 | 24 MPa | 60 °C | -40 °C | VCR Male | PUR-2W-M12 | 60 °C | -40 °C | 23 mA | 5 to 28 Vdc | -120 to -40 °C |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.