로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

멸균기 검증 시스템 - FDA 21 CFR Part 11
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 2개의 상품
| 제품 번호 / 가격 | Brand | Additional Features 1 | Battery Size and Type | Battery life | Calibration | Data Interface | Data Interface Note | Diameter | Form factor | Height | Materials | Measurement Type | Memory | Memory Note | Number of Measurements | Operating Humidity | Operating Temperature, Max | Operating Temperature, Min | Pressure Sensor Type | Probe Diameter | Probe Length | Process Temperature, Max | Process Temperature, Min | Real Time Recording | Samples,Max | Sampling Rate | Sampling Rate Note | Software Compatibility | Supply Power Type | Temperature Accuracy | Temperature Resolution | Temperature Sensor Type | Temperature Sensor Type Note | Time Accuracy | Weight | Measurement Pressure, Max | Measurement Pressure, Min | Pressure Calibrated Accuracy | Pressure Repeatability | Pressure Resolution | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OM-CP-AVS140-14,446,810 원4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | Complete systems used to perform autoclave validations for Temperature | 3.6V Li-ion | up to 1 yr | Digital calibration through software | USB | OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required, 125,000 baud | 25 mm | Benchtop | 40 mm | 316 Stainless Steel | Temperature | 32700 | 32,700 readings; software configurable memory wrap | 1 | 0 to 100% RH | 140 °C | -40 °C | MEMS Piezoresistive | 3.2 mm | 27 mm | 260 °C | -200 °C | May be used with PC to monitor ;and record data in real time | 33000 | 1 Hz (1 update/second) | One second up to once every 24 hours | XP SP3/Vista/7 and 8 (32-bit and 64-bit) | Battery | ± 0.1 °C | 0.01 °C | RTD | 100Ω Platinum RTD | ± 1 minute/month at 20 to 30ºC;(68 to 86ºF) (stand alone mode) | 120 g | - | - | - | - | - | |
OM-CP-AVS140-612,941,180 원6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | Complete systems used to perform autoclave validations for Temperature & Pressure | 3.6V Li-ion | up to 2 yr | Digital calibration through software | USB | OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required, 125,000 baud | 25.4 mm | Benchtop | 50.8 mm | Stainless Steel | Pressure, Temperature | 32700 | 32,700 readings; software configurable memory wrap | 2 | 0 to 100% RH | 140 °C | -40 °C | MEMS Piezoresistive | - | - | 260 °C | -200 °C | May be used with PC to monitor ;and record data in real time | 33000 | 1 Hz (1 update/second) | One second up to once every 24 hours | XP SP3/Vista/7 and 8 (32-bit and 64-bit) | Battery | ± 0.1 °C | 0.01 °C | RTD | 100Ω Platinum RTD | ± 1 minute/month at 20 to 30ºC;(68 to 86ºF) (stand alone mode) | 85 g | 5 bar | 0 bar | ± 0.03 | ± 0.5% FSR; ± 0.2% typical | 0.1 mbar |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.