| 제품 번호 / 가격 | Brand | Accuracy Detail | Approvals | Battery Size and Type | Battery life | Baud Rate | Calibration Accuracy | Data Interface | Data protection | Height | Humidity Range | Input Control Signal | Input Note | LED Indicators | Length | Materials | Measurement Pressure Type | Measurement Pressure, Max | Measurement Type | Memory | Memory Modes | Memory Note | Millivolt Range | Multi Start/Stop Mode Note | Number of Measurements | Operating Temperature, Max | Operating Temperature, Min | Process Connection Size | Process Connection Type | Real Time Recording | Resolution | Sampling Rate | Sampling Rate Note | Software | Start Modes | Stop Modes | Supply Power Type | Time Accuracy | Weight | Width | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OM-CP-BRIDGE101A-1000MV1,179,590 원4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | Calibration Accuracy : Strain: ±0.01% FSR; ±120 microvolts; Time Accuracy : ±1 minute/month at 20ºC (68ºF), stand alone data logging | CE | 3.6V Li-ion | 10 mo | 115200 | Strain : ±0.01% | USB | Access by password | 64 mm | 0 to 90% RH non-condensing | 0 to 2.5 V | ±1000 mV | Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition | 36 mm | ABS | N/A | 0 psi | Strain | 1,000,000 Readings | Yes | 1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/stop mode | ± 1200 mV | To Start the Device: Press and hold the pushbutton for five seconds, the green LED will flash during this time. The device has started logging, To Stop the Device: Press and hold the pushbutton for five seconds, the red LED will flash during this time. The device has stopped logging, Real Time Recording: The device may be used with PC to monitor and record data in real-time | 1 | 80 °C | -40 °C | N/A | N/A | The device may be used with PC to monitor and record data in real-time | Strain: 50 µV | 4 Hz (4 updates/second) | 4 Hz to 1 every 24 hours | Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit) | Delayed Start, Immediate Start | Manual Through Software | Battery | ±1 minute/month | 24 g | 16 mm | |
OM-CP-BRIDGE101A-150MV1,179,590 원6 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | Calibration Accuracy : Strain: ±0.01% FSR; ±16 microvolts; Time Accuracy : ±1 minute/month at 20ºC (68ºF), stand alone data logging | CE | 3.6V Li-ion | 10 mo | 115200 | Strain : ±0.01% | USB | Access by password | 64 mm | 0 to 90% RH non-condensing | 0 to 2.5 V | ±150 mV | Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition | 36 mm | ABS | N/A | 0 psi | Strain | 1,000,000 Readings | Yes | 1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/stop mode | ± 160 mV | To Start the Device: Press and hold the pushbutton for five seconds, the green LED will flash during this time. The device has started logging, To Stop the Device: Press and hold the pushbutton for five seconds, the red LED will flash during this time. The device has stopped logging, Real Time Recording: The device may be used with PC to monitor and record data in real-time | 1 | 80 °C | -40 °C | N/A | N/A | The device may be used with PC to monitor and record data in real-time | Strain: 5 µV | 4 Hz (4 updates/second) | 4 Hz to 1 every 24 hours | Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit) | Delayed Start, Immediate Start | Manual Through Software | Battery | ±1 minute/month | 24 g | 16 mm | |
OM-CP-BRIDGE101A-30MV1,179,590 원4 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | Calibration Accuracy : Strain: ±0.01% FSR; ±3 microvolts; Time Accuracy : ±1 minute/month at 20ºC (68ºF), stand alone data logging | CE | 3.6V Li-ion | 10 mo | 115200 | Strain : ±0.01% | USB | Access by password | 64 mm | 0 to 90% RH non-condensing | 0 to 2.5 V | ±30 mV | Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition | 36 mm | ABS | N/A | 0 psi | Strain | 1,000,000 Readings | Yes | 1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/stop mode | ± 30 mV | To Start the Device: Press and hold the pushbutton for five seconds, the green LED will flash during this time. The device has started logging, To Stop the Device: Press and hold the pushbutton for five seconds, the red LED will flash during this time. The device has stopped logging, Real Time Recording: The device may be used with PC to monitor and record data in real-time | 1 | 80 °C | -40 °C | N/A | N/A | The device may be used with PC to monitor and record data in real-time | Strain: 1 µV | 4 Hz (4 updates/second) | 4 Hz to 1 every 24 hours | Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit) | Delayed Start, Immediate Start | Manual Through Software | Battery | ±1 minute/month | 24 g | 16 mm |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.