로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

1/32, 1/16, 1/8 DIN 습도 및 온도 컨트롤러
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 162개의 상품 · 1 - 20 표시
| 제품 번호 / 가격 | Brand | A/D Conversion | Additional Features 1 | Control Action | Control Output | Data Interface | Display Size | Display Type | Display Type Note | Enclosure Ratings | Form factor | Input Note | Input Type | Measurement Type | Number of Inputs | Number of Outputs | Operating Temperature, Max | Operating Temperature, Min | Output Detail | Probe Dimensions Note | Probe Length | Ramp and Soak | Relative Humidity | Samples,Max | Supply Power Note | Supply Power Type | Supply Voltage | Data Interface Note | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CNITH-I8DH43-5-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | Relay, DC Pulse | Ethernet, RS232 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH33-5-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet, RS232 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D53-5-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH33-2-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet, RS232 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D53-2-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D43-5-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | Relay, DC Pulse | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D43-2-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | Relay, DC Pulse | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D33-5-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH44-2-EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | 2 DC Pulse | Ethernet | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T | |
CNITH-I16D33-2-C4EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet, RS232 | 46 mm (1.8 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH33-5-EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T | |
CNITH-I8DH33-5-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | RS232, RS485 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH33-2-EIT-DC가격 문의64 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | Ethernet | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T | |
CNITH-I8DH33-2-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SPDT Relay | RS232, RS485 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I8DH22-5-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | 2 SSR Relay | RS232, RS485 | 10.2 mm (0.4 in), 21 mm (0.8 in) | Dual 4 Digit LED, Horizontal | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/8 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D53-5-EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | Ethernet | 10.2 mm (0.40 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T | |
CNITH-I16D53-5-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 5 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | RS232, RS485 | 10.2 mm (0.40 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 127 mm (5") probe for iTH with 3 m (10') cable | 127 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D53-2-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | RS232, RS485 | 10.2 mm (0.40 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 | |
CNITH-I16D53-2-EIT-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output | Ethernet | 10.2 mm (0.40 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | Ethernet: Standards compliance IEEE 802.3 10Base-T | |
CNITH-I16D52-2-C24-DC가격 문의60 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | A/D Conversion: 12-bit RH and 14-bit temp Reading,Rate: 2 samples per sec max,Digital Filter: Programmable Decimal Selection: None, 0.1 for temperature and humidity | 2 inch Probe | Action: Reverse (heat) or direct (cool) | SSR Relay, Analog Output, Selectable | RS232, RS485 | 10.2 mm (0.40 in) | 4 Digit LED | Display: 4-digit, 9-segment LED i32, i16D, i8DV: 10.2 mm (0.40") i8: 21 mm (0.83") i8DH: 10.2 mm (0.40") and 21 mm (0.83") RED, GREEN and AMBER programmable colors for process variable, setpoint and temp units | IP65, NEMA Type 4X | 1/16 DIN | Input Accuracy/Range @ 25C - Non-condensing: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Temperature Accuracy/Range* ±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F) Resolution: 0.1%, 12bit for RH; 0.1°C, 14 bit for temperature Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature *Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C. | Digital | Temperature, Humidity | 2 | 2 | 50 °C | 0 °C | 2 solid state relays (SSR’s): 0.5 A @ 120/240 Vac continuous | 51 mm (2") probe for iTH with 1 m (3') cable | 51 mm | Single Ramp & Soak | 90% RH non-condensing | 2/sec | Low voltage power option: 20 to 36 Vdc, 24 Vac ±10%; 12 to 36 Vdc, 24 Vac ±10% for iTH-32 | DC | 20 to 36 Vdc | RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS485: Addressable from 0 to 199 |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.