로딩 중...
산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

70A 시리즈 저비용 가청 경보 표시기 (부저)
필터 또는 검색 기능을 사용하여 원하시는 모델을 찾으십시오.
총 8개의 상품
| 제품 번호 / 가격 | Brand | Operating Temperature, Max | Operating Temperature, Min | Operational Life | Relative Humidity | Relative Humidity Note | Sound Level | Storage Temperature, Max | Storage Temperature, Min | Supply Power Note | Supply Voltage | Working Life | 수량 / 장바구니 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
70A-4-220V81,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Warble tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 220 Vac | 5 years under normal operating conditions | |
70A-3-220V78,700 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Slow pulse tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 220 Vac | 5 years under normal operating conditions | |
70A-2-220V81,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Fast pulse tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 220 Vac | 5 years under normal operating conditions | |
70A-1-220V81,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Continuous tone, 95dB at 2900 Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 220 Vac | 5 years under normal operating conditions | |
70A-481,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Warble tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 120 Vac | 5 years under normal operating conditions | |
70A-281,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Fast pulse tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 120 Vac | 5 years under normal operating conditions | |
70A-384,930 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Slow pulse tone, 95dB at 2900Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 120 Vac | 5 years under normal operating conditions | |
70A-181,780 원2 weeks리드타임은 상황에 따라 달라질 수 있습니다. | OMEGA Engineering | 65 °C | -30 °C | 100 hours continuous operation at 65°C with maximum rated voltage applied; Intermitten: A duty cycle of 1 minute on, 5 minutes off, a minimum of 5000 times at room temperature with maximum rated voltage applied | 95% relative humidity at 40°C continuously for 100 hours | Series 70A temperature alarms will operate after having been subjected to 95% relative humidity at 40°C continuously for 100 hours; after removal from high humidity, the unit should be allowed to dry for a minimum of 4 hours at room temperature before operation | Continuous tone, 95dB at 2900 Hz | 85 °C | -40 °C | Surge Voltage: 20% over maximum rated voltage applied for <1 minute | 120 Vac | 5 years under normal operating conditions |
스페이스를 누른 채 마우스 휠을 움직이면 표를 좌우로 스크롤할 수 있습니다.