제품 사양
Brand:OMEGA Engineering
Accuracy:± 0.05 %
Accuracy Detail:Voltage and Current: ±0.05%, Thermoocouple: (J, K, T, E): ±1˚C, (N, L, U, P, W5, W3, LR, A1, A2, A3, M, E, B, R): ±2˚C, RTD: ±0.4˚C (CU10: ±1.0˚C)
Additional Features 1:3 Spare I/O Slots
Altitude,Max:2000 m
Burnout Current:10 µA
CMRR:120 dB
Configuration:ARM Cortex-A8, 1 GHz
Connection Note:2 Ports (One front, One back)
Cutout Dimensions:137 x 137 mm
Data Interface:Ethernet, Modbus
Depth Behind Panel:171 mm
Dielectric Strength:2300 Vac, 50/60 Hz for 1 minute between power terminal and earth
Display Note:LCD, 65K color with LED Backlight, MTBF Backlight: 30,000 hrs
Display Resolution:480 x 272 Pixels
Display Size:109 mm (4.3 in)
Display Type:LCD
Enclosure Ratings:IP20, IP65
Features:19 languages including English, Japanese, Chinese (simplified, traditional), French, German, Spanish, Swedish, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Brazil Portuguese and Czech
Height:144 mm
Input Current:± 26 mA
Input Note:Sensor Lead Resistance Effect: Thermocouple: 0.32 ppm of reading/Ω, 3-Wire RTD: 2.6˚C/Ω of resistance difference of two leads (based on ˚C measurement temperature for Pt100), 2-Wire RTD: 2.6˚C/Ω of resistance sum of two leads (based on ˚C measurement temperature for Pt100); RTD Input: ±20V, Thermocouple and Voltage Input: ±65V, Current (mA) Input: ±10V
Input Type:Thermocouple, RTD, Voltage, Current
Input Voltage:± 60 mVdc, ± 200 mVdc, ± 1 Vdc, ± 2 Vdc, ± 6 Vdc, ± 20 Vdc, ± 50 Vdc, 0.4 to 2 Vdc, 1 to 5 Vdc
Insulation Resistance:20 MΩ @ 500 Vdc
Isolation:1500 Vac at 50/60 Hz for 1 minute
Keypad Functions:Start/Stop Recording and turn off Display only (for quick re-start), Does not turn off Power to the unit
Length:189 mm
Measurement Type:Universal
Memory:256 MB Samples on 128 MB Flash Card
Mounting:1/2 DIN Panel Mount
NMRR:55 dB
Number of Inputs:6
Operating Temperature, Max:50 °C
Operating Temperature, Min:0 °C
RTD Type:2-, 3- or 4-wire RTD
Relative Humidity:20 to 90% RH
Relative Humidity Note:20 to 90% RH (non condensing), maximum relative humidity of 90% RH is for ambient temperature up to 38˚C (100˚F) decreasing linearly to 50% RH at 50˚C
Sampling Rate:10 Hz (10 updates/second)
Sensor Break Detection:Sensor opened for thermocouple, RTD and mV inputs; below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs; Within 1 second for thermocouple, RTD and mV inputs; 0.1 second for 4 to 20 mA and 1 to 5V inputs
Shock Resistance:30m/s² (3g) for Operation, 20 g for Transportation
Software:Standard Software supplied for Historical data viewing and Configuration, Optional: Data Acquisition Studio Software, OS:Windows XP/Vista/7/8
Storage Temperature, Max:70 °C
Storage Temperature, Min:-30 °C
Supply Power Note:90 to 250 Vac, 47 to 63 Hz,52 VA, 26 W max; 11 to 36 Vdc, 26 VA, 26 W max (optional)
Supply Power Type:AC
Supply Voltage:90 to 250 Vac
Temperature Measurement Range:J: -120 to 1000°C, K: -200 to 1370 °C, T: -250 to 400 °C, E: -100 to 900 °C, R: 0 to 1780 °C, S: 0 to 1780 °C, N: -250 to 1300 °C, B: 0 to 1820 °C, RTD: -200 to 850°C
Thermal Effects:±0.1 µV ±15 ppm of reading for all inputs except mA, ±30 ppm of reading for mA input
Thermocouple Type:J, K, T, E, N, R, S, B, C, W5, W3, L, U, P, A1, A2, A3, M, LR
Vibration Resistance:10 to 55 Hz, 10 m/s² for 2 hours
Width:144 mm