실시간 문의하기제품 사양
Brand:OMEGA Engineering
Acceleration Range:± 15 g , ± 100 g , ± 300 g
Accelerometer Sensor Type:MEMS
Accuracy Detail:Calibration Accuracy : Humidity : ±3 %RH (±2 %RH typical at 25 °C), Pressure : ±1.5 mbar at 25 °C; at 750 mbar, Temperature : ±0.5 °C (+5 °C to +60 °C); Time Accuracy : 10 seconds/month (at 0 °C to 50 °C)
Approvals:CE
Battery Size and Type:Li-ion
Battery life:up to 3 mo
Calibration:Digital calibration through software and automatically recorded within device
Calibration Accuracy:Humidity : ±3% RH, Temperature : ±0.5 °C, Pressure : ±1.5 mbar, Accelerometer : ±0.3 g/±2.0 g/±6.0 g
Calibration Option:NIST
Data Interface:USB
Data protection:Access by password
Enclosure Ratings:IP64
Frequency Response:>1000 Hz (15 g), >500 Hz (100 g, 300 g)
Height:86 mm
Humidity Range:0 to 95% RH non-condensing
Length:43 mm
Materials:Aluminum
Measurement Pressure Type:N/A
Measurement Pressure, Max:1300 mBar
Measurement Pressure, Min:100 mBar
Measurement Type:Temperature, Humidity, Pressure, Shock
Measuring Temperature Range, Max:60 °C
Measuring Temperature Range, Min:-20 °C
Memory:3,593,358 Readings
Memory Note:3,593,358 readings (598,893 per channel, all channels in use)
Millivolt Range:N/A
Number of Measurements:N/A
Operating Temperature, Max:60 °C
Operating Temperature, Min:-20 °C
Pressure Sensor Type:Silicon Strain Gage
Process Connection Size:1/4 in
Process Connection Type:N/A
Real Time Recording:May be used with PC to monitor and record data in real time at a 1 second sample rate
Relative Humidity Sensor Type:Capacitive Polymer
Resolution:Pressure : 0.05 mbar, Humidity : 0.1% RH, Temperature : 0.1°C, Acceleration : 0.02 g , 0.05 g, 0.2 g
Sampling Rate:1024 Hz (1024 updates/second)
Sampling Rate Note:1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure and humidity sampled approx. every 2 seconds at intervals shorter than 2 seconds. Otherwise, sampled at the reading rate.
Software:Standard Software version 4.2.15.0 or later Secure Software version 4.2.14.0 or later, Windows XP SP3/7/8/10
Start Modes:Delayed Start, Immediate Start
Supply Power Type:Battery
Temperature Sensor Type:Silicon Diode
Time Accuracy:10 seconds/month
Weight:227 g