산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

DwyerOmegaOM-CP-RFCurrent2000A-Series

OM-CP-RFCURRENT2000A-3A

해외배송

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 6 weeks리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Brand:OMEGA Engineering
Alarm Note:User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
Band Frequency:2.405 to 2.475 GHz
Band Frequency Note:ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate
Battery Size and Type:Li-ion, 9V
Battery life:4 yr, typical with reading interval of 15 min
Baud Rate:250000
Calibration:Digital Calibration through Software
Calibration Accuracy:Current: ± 0.0001A
Calibration Date:Automated
Configuration:Omega Engineering Data Recording Software, Windows PC
Conversion Time:150 milliseconds
Current Measurement Range:± 3 A
Current Resolution:0.01 mA
Current, Max:± 5A for 2 Seconds
Data Interface:Wireless, USB
Data Interface Note:USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT/ OM-CP-RFC1000-EXT-EUR/OM-CP-RFC1000-IP69K required for wireless operation
Display Type:LCD
Frequency Rejection:50 to 60 Hz
Height:0.95 in
Impedance Input:0.02 Ω
Input Type:External
LED Functionality:Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition
Length:3.5 in
Materials:Plastic
Measurement Type:Current
Memory Modes:Yes
Nominal Current:± 3 A
Number of Measurements:1
Operating Temperature, Max:60 °C
Operating Temperature, Min:-20 °C
RF Frequency:2.45 GHz
RF Frequency Note:2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Real Time Recording:The device may be used with PC to monitor and record data in real-time
Relative Humidity:0 to 95% RH non-condensing
Response Time:Current: 0.15 sec
Response Time Note:Current: 0.15 seconds at sensor
Samples,Max:32256 Samples, Interval Selectable 1 Sec to 24 hrs
Sensor Type:Current Sensor
Software:XP SP3/Vista/7 and 8 (32 and 64-bit)
Start Modes:Delayed Start, Immediate Start
Stop Modes:Manual via remote software connection, At set date and time, At set Duration
Supply Power Note:Max Voltage Between Inputs to Ground: 2.5 V
Supply Power Type:Battery
Temperature Coefficient:< ± 50 ppm/°C typical
Time Accuracy:± 1 minute/month
Weight:4.1 oz
Width:3.3 in