산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

DwyerOmegaKW1850

KW320Q-P1-D-W-PC

해외배송

Panel Upgrade, same as KW320Q-P1-D-W-XX installed in NEMA 4X Enclosure w/ labeled and prewired supply voltage and CT connections

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 7 weeks리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Accuracy:0.1 Class
Applications:Building and Maintenance, Control Panel, Environmental Monitoring, Industrial and Manufacturing
Baud Rate:9600, 19200, 38400, 76800
Compliance Note:Measurement Standard: IEC 62053-22; ANSI C12.20 Environmental Standard: IEC 60068-2 Safety Standard: IEC 61010-1, UL 61010-1, IEC 61557-12 EMC Standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4 Outlines Standard: DIN 43700, ANSI C39.1
Connection Note:Two pluggable pre-cut holes to feed wiring, fused terminal blocks for voltage connections pre-installed, color-coded and labelled
Data Format:8 data bits:no parity:1 stop bit
Data Interface:Modbus, BACnet MS/TP, BACnet Over IP, IEC 61850, Modbus®-TCP, HTTP/HTTPs Webserver, SMTP Email, SNMP, HTTP/HTTPs Push, FTP Post, sFTP Server, WiFi
Display Type:LCD
Electrical Connection:Screw Terminal
Enclosure Material:Flame retardant polycarbonate
Enclosure Ratings:IP66, NEMA Type 4X
Frequency:50/60 Hz
Fuse Rating:600 VAC/1A
Height:7.34 in
Impedance Input:2MΩ/Phase
Input_Current Note:120% of current sensor rating (mV CTs) to maintain accuracy. Up to 6000 Amps w/ Rogowski Coils
Length:7.88 in
Materials:Polycarbonate
Memory Backup:8 GB Datalogging
Mounting:ANSI C39.1 (4” Round) or an IEC 92mm DIN (Square) form
Network and Communications:BACnet Device Instance Number: 1 (Default); Field adjustable from 1 to 4194302; Max Station: 127 MS/TP Masters (MAC Addresses is 0 to 127); Supported Baud Rates: BACnet MS/TP Protocol: 9600, 19200, 38400, 76800 Baud Rate (38400 BACnet Default) Modbus RTU Protocol: 1200, 2400, 4800, 9600, 19200, 38400 Baud Rate (19200 Modbus Default)
Number of Channels Note:4 Channels, 0.400 VAC max, 333 mV CTs or 0 to 6000 Amps with Rogowski Coils (Field Selectable); Voltage Channels : 400 Volts AC (L-N), 690 VAC (L-L), 45Hz - 65Hz, 300Hz - 500Hz
Number of Inputs:4
Operating Distance, Max:1200 m
Operating Humidity:5 to 95% RH, non-condensing
Operating Temperature, Max:158 °F
Operating Temperature, Min:-13 °F
Operating Voltage, Min:10 V
Power Consumption:5 W
Protection:External 1A/250VAC Fuse
Resolution:63rd Harmonic (50Hz or 60Hz type) or 15th Harmonic (400Hz type)
Series ID:KW320
Software:Acuview Utility Software, Windows Based; (USB-RS485 converter is required to connect to computer)
Storage Temperature, Max:185 °F
Storage Temperature, Min:-40 °F
Supply Voltage:100 to 415 Vac, 100 to 300 Vdc
Termination:120 to 300 Ω
Update Rate:Accumulated Parameter Update Rate: 1 sec ; Real Time Parameter Update Rate: <20 ms
Voltage Measurement Range:100 to 400 Vac (L-N), 100 to 690 Vac (L-L), 100 to 400 Vac rms (1 phase)
Weight:8 lb
Width:11.81 in
Wire Gauge:22 to 14 AWG
Withstand Voltage:3250 Vac