산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

DwyerOmegaISD-TH-Series

ISD-TH-5-CAL-3-HU

해외배송

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 64 weeks리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Brand:OMEGA Engineering
AC Adaptor Operating Temperature:0 to 40 °C
Accuracy Detail:Accuracy/Range at 25°C: Non-Condensing: 10 to 90%: 2.75% RH, 5 to 10% and 90 to 95%: ± 3%, 0 to 5% and 95 to 100%: ± 4%
Alarm:Alarm I/Os: Two contact inputs, TTL 0.5 mA with 10K pull-up; one open collector output 150 mA @ 30 Vdc
Approvals:CE, FCC-B
Battery Operating Temperature:-18 to 55 °C
Battery Size and Type:Alkaline 9V
Cable Length:10 ft
Cable Temperature, Max:125 °C
Cable Temperature, Min:-40 °C
Calibration Option:5 POINT NIST
Certifications:NIST Traceable Calibration
Configuration:Internal Web UI
Data Interface:Ethernet
Data Interface Note:Ethernet : (RJ45) Fixed or auto negotiating 10/100BASE-T, AUTO MDI/MDIX Protocols: TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
Display:LCD
Display Note:32 digits 4.8 x 9.7 mm (0.19 x 0.38")
Electrical Connection:DIN 43650 C (solenoid valve)
Form factor:Wall mount bracket
Height:1.31 in
Hysteresis:± 1% RH
Input Type:External
Length:4.69 in
Logging Modes:Fixed interval
Measurement Type:Relative Humidity, Temperature
Memory:2 GB SD Flash Card
Memory Note:8 months of data storage at 1 second recording intervals or 7 years at 10 sec intervals
Non-Linearity:± 3%
Number of Measurements:2
Number of Relays:2
Operating Temperature, Max:60 °C
Operating Temperature, Min:0 °C
Probe Diameter:0.63 in
Probe Length:5 in
Probe Style:Industrial Probe
RH Measurement Range:0 to 100% RH
RH Resolution:0.1%, 12 bit
Relative Humidity Accuracy:± 2.75% for 10 to 90%; ± 3% for 5 to 10% and 90 to 95%; ± 4% for 0 to 5% and 95 to 100%
Relay Output:1.5 A @ 30 Vdc
Repeatability:± 0.1%
Response Time:Temperature: 5 to 30 sec, RH: 8 sec
Response Time Note:Temperature: 5 to 30 seconds, tau 63%, RH: 8 seconds, tau 63%
Samples,Max:85k Samples, Interval 1 sec, 1 Second recording intervals or 7 years at 10 sec intervals
Sensor Type:Probe
Storage Temperature, Max:85 °C
Storage Temperature, Min:-40 °C
Supply Current:0.5 A
Supply Power Note:AC Power Adaptor (Included):, Nominal Output: 9 Vdc @ 0.5 A , Back-Up Battery: 9 Vdc, Alkaline (included)
Supply Power Type:DC/Battery
Supply Voltage:9 to 12 Vdc
Temperature Accuracy:± 0.5 to ± 1.5°C
Temperature Measurement, Max:124 °C
Temperature Measurement, Min:-40 °C
Temperature Repeatability:± 0.1 °C
Temperature Resolution:0.1 °C
Weight:1.08 lb
Width:6.13 in