산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

DwyerOmegaiServer2-Probe

IS2-THB-B-CAL-3

해외배송

Basic - Environmental Probe Kit (CAL-3)

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 9 weeks리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Brand:OMEGA Engineering
AC Adaptor Operating Temperature:0 to 40 °C
Accuracy Detail:Pressure: Accuracy Over Full Range: ± 6 mbar from 300 to 1100 mbar, Accuracy @ 25 °C: ± 4 mbar from 700 to 1100 mbar
Alarm:Two contact inputs TTL 0.5 mA; one open collector output 150 mA @ 30 V DC
Approvals:CE, UKCA, ICES-3(B)/NMB-3(B), FCC
Battery Operating Temperature:-18 to 55 °C
Battery Size and Type:Alkaline 9V
Cable Temperature, Max:125 °C
Cable Temperature, Min:-40 °C
Calibration Option:5 POINT NIST
Certifications:NIST Traceable Calibration
Configuration:Internal Web UI
Data Interface:Ethernet, USB
Data Interface Note:Ethernet (RJ45): 1x port (Power over Ethernet available on qualifying models) Supported Protocols: TCP, UDP, SNMP, SNTP, ARP, ICMP, DNS, HTTP, and Telnet
Display Type:None
Electrical Connection:M12 8 pin Female
Form factor:Wall Mount
Height:4 in
Hysteresis:± 0.8%
Input Type:External
LED Indicators:100 BASE-T, Network Link and Activity, Internet
Length:12.99 in
Logging Modes:Fixed interval
Measurement Pressure, Max:1100 mBar
Measurement Pressure, Min:300 mBar
Measurement Type:Barometric Pressure, Relative Humidity, Temperature
Memory:11 GB
Number of Measurements:3
Operating Temperature, Max:60 °C
Operating Temperature, Min:0 °C
Pressure Accuracy:± 6 mbar
Probe Type:Smart Probe
Relative Humidity:0 to 80 % non-condensing
Relative Humidity Accuracy:± 2.5% RH
Response Time:Temperature: < 1 sec, RH: 8 sec
Response Time Note:Temperature: Less than 1 second, RH: 8 seconds
Samples,Max:75M Samples, Interval 1 Sample / Second, Continue logging up to 10 000 data points for a period of 96 hours
Sensor Type:Probe
Software:Access web server using any modern web browser such as Chrome, Edge, or Firefox on the same local network; Firmware upgrade from Internet; Export probe data log to CSV files
Storage Temperature, Max:85 °C
Storage Temperature, Min:-40 °C
Supply Current:1.5 A
Supply Power Note:Back-Up Battery: 9 V DC, alkaline, Power Consumption: 4 W, AC Power Adapter (Included) Nominal Output: 12 V DC @ 1.5 A, Power over Ethernet: IEEE 802.3AF, 44 V - 49 V, Power Consumption under 10 W
Supply Power Type:DC/Battery
Supply Voltage:9 to 12 Vdc
Temperature Accuracy:± 0.3 °C
Temperature Measurement, Max:85 °C
Temperature Measurement, Min:-40 °C
Temperature Repeatability:± 0.15 °C
Weight:1.44 lb
Width:6.13 in