산업용 측정 장비 · 제어 부품 · 글로벌 브랜드 통합 쇼핑몰

DwyerOmegaDP6000

DP6060-7H3

해외배송

1/8 DIN Dual Input Process Panel Meter

판매 가격
가격 문의
수량

재고: 0개국내 재고가 없어도 주문 가능합니다. 주문 시 해외 재고를 확인합니다.

무료 배송 10만원 이상

납기: 문의리드타임은 상황에 따라 달라질 수 있습니다.

연구비카드 사용가능
실시간 문의하기
제품 사양
Brand:OMEGA Engineering
Additional Features 1:Sunlight Readable
Baud Rate:300 to 19200
Calibration:Calibrated at the factory. Recalibration is recommended at least every 12 months
Category of Overvoltage:II
Category of Overvoltage Note:Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Control Output:None
Data Interface:Modbus RTU
Data Interface Note:Protocol: Modbus RTU Meter Address/Slave ID: 1 – 247 Baud Rate: 300 to 19,200 bps Transmit Time Delay: Programmable between 0 and 199 ms Data: 8 bit (1 start bit, 1 or 2 stop bits) Parity: Even, odd, or none with 1 or 2 stop bits Byte-to-Byte Timeout: 0.01 to 2.54 seconds Turn Around Delay: Less than 2 ms (fixed)
Digital I/O Note:Channels: 4 digital inputs and 4 digital outputs per module System: Up to 2 modules for a total of 8 inputs and 8 outputs Digital Input Logic: High: 3 to 5 Vdc Low: 0 to 1.25 Vdc Digital Output Logic: High: 3.1 to 3.3 Vdc Low: 0 to 0.4 Vdc Source Current: 10 mA maximum Sink Current: 1.5 mA minimum +5 V Terminal: To be used as pull-up for digital inputs only
Display Color:Red
Display Size:15 mm (0.60 in)
Display Type:6 Digit Dual - Line -Sunlight Readable
Display Type Note:Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking Upper Display: 15 mm (0.60") high Lower Display: 12 mm (0.46") high Display Intensity: 8 intensity levels Display Update Rate: 5 per second Overrange: Display flashes 999999 Underrange: Display flashes -99999 Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
Electrical Connection:Screw Terminal
Electrical Connection Note:Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/o, and serial communication adaptors
Enclosure Material:Plastic
Enclosure Ratings:IP65, NEMA Type 4X
Form factor:1/8 DIN
Functions:Noise Filter: Programmable from 2 to 199 (0 will disable filter) ;Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span ;Cyber Security: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/ reset points; Pass 3: Restricts all programming, function keys, and digital inputs
Fuse Rating:5 A delayed
Height:62 mm
Input Type:Current, Voltage
Input Type Note:Input: Field selectable: 0 to 20 mA, 4 to 20 mA, ±10 Vdc (0 to 5, 1 to 5, 0 to 10V), MoDbuS PV (slave) Accuracy: ±0.03% of calibrated span ±1 count, square root and programmable exponent accuracy range: 10 to 100% of calibrated span Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient Signal Input Conditioning Function: Linear, square root, programmable exponent, or round horizontal tank volume calculation Multi-Point Linearization: 2 to 32 points for PV or PV1; 2 to 8 points for PV2 (dual-scale level feature) Programmable Exponent: 1.0001 to 2.9999 Low-Flow Cutoff: 0 to 999999 (0 disables cutoff function) Decimal Point: Up to 5 decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd Calibration Range: 4 to 20 mA: Minimum span; input 1 and Input 2: 0.15 mA ±10 V: Minimum span; input 1 and 2: 0.10 V An Error message will appear if input 1 and input 2 signals are too close together Input Impedance: Voltage Ranges: Greater than 1 MΩ Current Ranges: 50 to 100 Ω (depending on resettable fuse impedance) Input Overload: Current input protected by resettable fuse, 30 Vdc max; fuse resets automatically after fault is removed
Isolation:4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Length:143 mm
Memory:Non-Volatile Memory : All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Mounting:1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Normal Mode Rejection:Greater than 60 db at 50/60 Hz
Number of Inputs:2
Operating Temperature, Max:65 °C
Operating Temperature, Min:-40 °C
Output Configurations:Analog Current
Programmable Functions:Filter Bypass, Noise Filter, Security
Programming:4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
Relative Humidity:0 to 90% non-condensing
Sampling Rate:5 Hz (5 updates/second)
Storage Temperature, Max:85 °C
Storage Temperature, Min:-40 °C
Supply Power Note:85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4
Supply Power Type:DC
Supply Voltage:12 to 24 Vdc
Tightening Torque:Screw terminal connectors: 5 lb-in
Weight:269 g
Width:119 mm
Wire Gauge:22 to 12 AWG